![]() |
...Testing Equipment for Current and Voltage Transformer Test Testing for current transformer equipment: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Testing...
Verified Supplier
|
![]() |
...Current Transformer CT PT Test Equipment Test System 1) Error test (Ratio error and Phase error) of CT&PT 2) Manual operation or operation through PC by software Test range: Measure Item Test Range CT accuracy test Rated primary current range: 1A-3200A Rated secondary current: 5A, 1A Operation range: (1%-120%).In PT accuracy test...
Site Member
|
![]() |
...Current Transformer CT PT Test Equipment Test System 1) Error test (Ratio error and Phase error) of CT&PT 2) Manual operation or operation through PC by software Test range: Measure Item Test Range CT accuracy test Rated primary current range: 1A-3200A Rated secondary current: 5A, 1A Operation range: (1%-120%).In PT accuracy test...
Site Member
|
![]() |
...Current Transformer Test Set for Portable Reference Standard Features & Functions Can be used for on-site verification of current and electromagnetic type voltage transformer ratio difference and difference, and also can measure ratio difference and angle difference of any percentage between 1% and 200% of the current; can be used to measure the ratio and polarity of transformer...
Verified Supplier
|
![]() |
Current transformer on Site Error Test CT Live Calibration Bench The device is developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity, trivial operation when on site test current transformer, voltage transformer...
Verified Supplier
|
![]() |
...Test Set Current Transformer Analyzer Discription of CT Test Set Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test...
Verified Supplier
|
![]() |
...Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Tests for Voltage Transformer: 1 Turns ratio test...
Active Member
|
![]() |
...test, CT/PT Polarity test, CT/PT Transformation ratio test, automatically calculate error curve of any CT point. Input voltage Output scope Measuring scope Measuring degree Device main engine 220V 0~600V,0~20A 0~600V,0~20A 0.5% 380V 0~1000V,0~20A 0~1000V,0~20A 0.5% 220V 0~600A 0~600A Transformation...
Active Member
|
![]() |
...test, CT/PT Polarity test, CT/PT Transformation ratio test, automatically calculate error curve of any CT point. Input voltage Output scope Measuring scope Measuring degree Device main engine 220V 0~600V,0~20A 0~600V,0~20A 0.5% 380V 0~1000V,0~20A 0~1000V,0~20A 0.5% 220V 0~600A 0~600A Transformation...
Active Member
|
Recommended Quality Verified Suppliers